Rapid response through the simple and quick method diagnosis,
minimizing the economic loss of customers.
PEDV Ag Test Kit
[LGM-PPG-11] & [LGM-PPG-12]
Porcine epidemic diarrhea has a high mortality rate from the viral, porcine epidemic diarrhea virus (PEDV), infection and its symptoms are similar to those of the transmissible gastroenteritis virus (TGEV) infection, requiring accurate and fast diagnosis.
The RIDX® PEDV Ag Test Kit is a lateral flow chromatographic immunoassay for the qualitative detection of PEDV antigens in porcine feces. This kit shows two letters which are the test (T) line and the control (C) line on the surface of the device. If the PEDV antigen exists in the sample, it binds to the gold-conjugated PEDV monoclonal antibody. The antigen-antibody complex moves through the membrane by capillary force and responds to the PEDV monoclonal antibody on the test line, resulting in a red line. The control line indicates that the test is performed correctly and should appear when the test is complete.
The highly selective and sensitive two monoclonal antibodies to PEDV are used as capture and detector in the kit. The RIDX® PEDV Ag Test Kit can detect PEDV antigens in porcine feces with high accuracy.
Porcine diarrhea feces
• RIDX PEDV Ag test device (10 or 2 tests)
• Sample dilution buffer (10 or 2 vials)
• Disposable swab (10 or 2 ea)
• Disposable dropper (10 or 2 ea)
• Instructions for use (1 sheet)
• Sensitivity: 98.3% (228/232) vs. RT-PCR
• Specificity: 98.6% (276/280) vs. RT-PCR
• Diagnostic Agreement: 98.4% (504/512) vs. RT-PCR
• Limit of Detection: 1x102 TCID50/mL
• No cross-reactivity with other porcine diarrheal pathogens (BVDV, CSFV, PCV2, PRRSV, ROTA, and TGEV)
• 10 Tests/Kit [LGM-PPG-11]
• 2 Tests/Kit [LGM-PPG-12]
1. All reagents and samples must be at room temperature (15~30℃/59~86℉) before use.
2. Collect fecal samples using a swab.
3. Put the swab into the sample dilution buffer and stir the solution with the swab to disperse the sample into the buffer (approximately 10 seconds).
4. Remove the swab from the sample dilution buffer.
5. Wait for 20 seconds to settle down the large particles.
6. Remove the test device from the pouch and place it on a flat and dry surface.
7. Take the supernatant of the sample solution in the tube by using a disposable dropper.
8. Apply 4 drops of the sample solution into the sample hole (S) on the device, drop by drop vertically.
9. Read test result at 10 minutes.